Chemical Resistance
Radiation Resistance
Long Service Life

GNJ500-03

GNJ500-03 is a high-temperature fire-resistant cable featuring stranded pure nickel conductor, insulation tape, glass fiber sheath and sintered PTFE outer coating. Rated at 300/500V, it works reliably from -65°C up to 300°C. The inorganic glass fiber sheath is non-combustible, chemically stable and mechanically strong. Its pure nickel conductor delivers outstanding oxidation resistance under high heat, and the cable is RoHS compliant for industrial high-temperature wiring in ovens, furnaces and metallurgical facilities.

29 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Structures

    • Conductor: Stranded pure nickel wires. Wire properties per GB/T3120-1996. Conductor construction per GB/T3956-2008.
    • Insulation: Insulation tape.
    • Sheath: Glass fiber material. Properties per JC/T1831-2008.
    • Outer Coating: Sintered PTFE aqueous dispersion. Finished cable dimensions inspection method per GB/T2951-2008. Finished cable electrical performance inspection method per GB/T3048-2007.

    Technical data

    • Temperature range: -65~+300°C
    • Rated voltage: U0/U 300/500V
    • Test voltage: 1500V
    • Bending radius: fixed installation ≥ 20×OD

    Product Features

    • Glass fiber sheath – inorganic fiber with non-combustibility; excellent chemical resistance; low water absorption; high mechanical strength; good insulation; strong heat resistance.
    • Pure nickel stranded conductor provides excellent high-temperature oxidation resistance.
    • Free of hazardous substances, compliant with ROHS standard.

    Applications

    Designed for applications with extreme connection/ambient temperatures in special environments (metallurgy, petroleum, chemical, natural gas, kerosene) requiring fire-resistant electrical installations. Typical use cases: Steel plants, rolling mills, foundries, glass/ceramic factories, electromechanical equipment, drying tunnels, baking ovens, heating lamps, electric appliances, furnaces, power plant construction, thermoplastic molding processes. Limitations: Moderate voltage rating and fire resistance. Special structural design allows use in humid environments (max 220 °C) and dry environments above this temperature.

    Technical Parameters:

    Nominal cross section (mm²) Voltage class (V) Conductor construction: Number/size (mm) Insulation thickness (mm) Final outer diameter (mm) The maximum resistance value of the conductor at 20℃ (Ω/km) The length of package (m)
    0.5 300 7/0.30 0.15 1.6±0.2 195 200
    500 0.25 1.8±0.2
    0.75 300 11/0.30 0.15 1.9±0.2 130 200
    500 0.25 2.2±0.2
    1.0 300 14/0.30 0.15 2.0±0.2 100 200
    500 0.25 2.3±0.2
    1.5 300 30/0.25 0.15 2.3±0.2 66 100
    500 0.25 2.6±0.2
    2.5 300 50/0.25 0.15 2.8±0.2 40 100
    500 0.25 3.0±0.2
    4.0 300 56/0.30 0.15 3.5±0.3 25 100
    500 0.25 3.7±0.3
    6.0 300 84/0.30 0.15 4.4±0.3 16.5 100
    500 0.25 4.6±0.3
    10 300 133/0.32 0.15 5.5±0.3 9.5 100
    500 0.25 5.8±0.3