Chemical Resistance
Radiation Resistance
Long Service Life

AWM1911

AWM1911 is a high-voltage PFA insulated wire approved to UL758 & UL1581 standards. It adopts flexible stranded copper conductor with tinned, silver-plated or nickel-plated options. It operates stably from -65°C to 250°C with rated voltage covering 5KV~50KV. This wire features outstanding corrosion resistance, ultra-low high-frequency loss, self-extinguishing flame performance and RoHS compliance. It is widely used for gas & automotive ignition systems, microwave and TV internal high-voltage wiring, instrument high-voltage connections and other electronic high-voltage scenarios.

26 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Structures

    • Conductor: Flexible stranded conductor of single or multiple tinned, silver-plated, or nickel-plated copper wires. Tinning performance complies with GB/T4910-2022. Silver-plating performance complies with JB/T3135-2024. Nickel-plating performance complies with GB/T11019-2021. Conductor structure conforms to UL758&UL1581 or customer requirements.
    • Insulation: Soluble Polytetrafluoroethylene (PFA). Insulation material performance complies with UL758&UL1581, Finished wire/cable electrical performance testing methods comply with UL758&UL1581.

    Technical Data

    • Temperature Range: -65 to +250°C
    • Rated Voltage: U0/U 5KV to 50KV
    • Test Voltage: Determined based on the rated voltage
    • Insulation Resistance: Should be no less than 1.0×10³MΩ·km at 20°C
    • Radiation Resistance: up to 1×10⁵ cJ/kg (up to 1 Mrad)

    Product Features

    • Excellent corrosion resistance: Resists oils, strong acids, strong alkalis, strong oxidizers, and microorganisms; prevents fungal growth.
    • Superior electrical insulation: Low, nearly frequency-independent dielectric properties; high voltage resistance; low high-frequency loss; moisture absorption <0.01%; minimal water vapor permeability (~0.18 mgr/cm²/24h); high insulation resistance.
    • Non-flammable, self-extinguishing. Flame retardancy complies with DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1 (Equivalent to DIN VDE 0472 Part 804 Test Method B).
    • Free from hazardous substances, compliant with ROHS standard.

    Applications

    • Gas ignition systems, automotive ignition systems
    • Internal high-voltage wiring for televisions and microwave ovens
    • Instrumentation high-voltage connections
    • Other high-voltage applications in electronic/electrical equipment

    Technical Parameters:

    Conductor Insulation Max. At 20℃, the maximum
    direct current resistance
    of the conductor (Ω/km)
    The Length
    of Package
    (m)
    5KV 10KV 15KV 20KV 25KV
    AWG Conductor
    Structure
    Cross-
    sectional
    Area
    (m²)
    Thickness
    (mm)
    OD
    (mm)
    Thickness
    (mm)
    OD
    (mm)
    Thickness
    (mm)
    OD
    (mm)
    Thickness
    (mm)
    OD
    (mm)
    Thickness
    (mm)
    OD
    (mm)
    Nickle
    plating
    Silver
    plating
    24 7/0.2 0.22 0.50 1.60 0.60 1.80 0.65 1.90 0.70 2.00 0.75 2.10 94.2 89.2 305
    22 19/0.15 0.33 0.50 1.75 0.60 1.95 0.65 2.05 0.70 2.15 0.75 2.25 59.4 56.4 305
    20 19/0.20 0.50 0.50 2.00 0.60 2.20 0.65 2.30 0.70 2.40 0.75 2.50 36.7 35.3 305
    18 19/0.23 0.80 0.50 2.20 0.60 2.40 0.65 2.50 0.70 2.60 0.75 2.70 23.2 22.2 305
    17 19/0.26 1.0 0.50 2.30 0.60 2.50 0.65 2.60 0.70 2.70 0.75 2.80 18.3 17.6 305
    16 19/0.30 1.31 0.50 2.50 0.60 2.60 0.65 2.80 0.70 2.90 0.75 3.00 14.6 14.0 305
    14 19/0.37 2.08 0.50 2.85 0.60 3.05 0.65 3.15 0.70 3.25 0.75 3.35 8.96 8.78 305
    12 19/0.48 3.31 0.50 3.40 0.60 3.60 0.65 3.70 0.70 3.80 0.75 3.90 5.64 5.53 305
    10 37/0.43 5.30 0.50 4.05 0.60 4.25 0.65 4.30 0.70 4.40 0.75 4.50 3.54 3.47 305