Chemical Resistance
Radiation Resistance
Long Service Life

AGG-DC

AGG-DC high voltage silicone wire adopts flexible stranded tinned copper conductor and silicone rubber insulation. It operates reliably from -60°C to 200°C with short-time heat resistance up to 220°C, covering high DC voltage grades from 5KV to 100KV. This cable features great flexibility, outstanding insulation performance, waterproof, mildew-proof and anti-aging properties. It supports halogen-free and flame retardant options and meets RoHS requirements. It is widely used for high-voltage ignition of gas equipment and vehicles, internal high-voltage wiring of microwave ovens and TVs, as well as high-voltage connection of instruments and electrical devices.

29 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Structures

    • Conductor: Flexible stranded tinned copper wire. Tinned copper wire performance complies with GB/T4910-2022. Conductor structure conforms to GB/T3956-2008 or customer requirements.
    • Insulation: Silicone Rubber. Insulation material performance complies with GB/T2951-2008. Outer diameter testing complies with GB/T2951-2008. Electrical performance testing complies with GB/T3048-2007.

    Technical Data

    • Temperature range: -60 to +200°C, Short-term temperature resistance: +220°C
    • Rated voltage: 5KV, 10KV, 15KV, 20KV, 25KV, 30KV, 50KV, 100KV
    • Test voltage: According to the rated voltage
    • Insulation resistance: At 20°C, it should be no less than ≥ 100MΩ·km
    • Radiation resistance: up to 20×10⁶ cJ/kg (up to 20 Mrad)

    Product Features

    • Eco/Biological: Odorless, non-toxic, excellent anti-thrombogenicity & bio-inertness. Electrical: Superior insulation, stable high-temperature performance. Chemical: Moderate oil/solvent resistance. Durability: Exceptional aging resistance, waterproof & mildew-proof for humid environments. Mechanical: Highly flexible with excellent elasticity for easy installation.
    • Fire Safety Options: Halogen-free: Complies with DIN VDE 0482-267, EN 50267-2-2, IEC 60754-2 (≡ DIN VDE 0472-813). Flame Propagation: Passes DIN VDE 0482-332-1-2 / EN 60332-1-2 / IEC 60332-1 (≡ DIN VDE 0472-804-B)
    • Compliance: ROHS certified, hazardous substance-free

    Applications

    • High-voltage ignition systems: Gas-fired equipment, automotive
    • Internal HV wiring: Televisions, microwave ovens
    • Instrumentation HV connections
    • HV applications in electronic/electrical equipment

    Technical Parameters:

    Voltage class
    (KV)
    Nominal cross section
    (mm²)
    Conductor structure
    Number/size(mm)
    Insulation
    thickness
    (mm)
    Average
    O.D
    (mm)
    At 20℃, the maximum direct current
    resistance of the conductor (Ω/km)
    5 0.2 7/0.20 1.00 2.60 95
    0.35 19/0.16 1.00 2.80 53.1
    0.5 16/0.20 1.20 3.20 40.1
    0.75 24/0.20 1.20 3.60 26.7
    1.0 32/0.20 1.30 4.00 20
    1.5 30/0.25 1.50 4.60 13.7
    2.5 49/0.25 1.60 5.20 8.21
    4.0 56/0.30 1.60 5.20 5.09
    10 0.2 7/0.20 1.30 3.40 95
    0.35 19/0.16 1.30 3.60 53.1
    0.5 16/0.20 1.50 4.20 40.1
    0.75 24/0.20 1.50 4.40 26.7
    1.0 32/0.20 1.80 5.20 20
    1.5 30/0.25 1.80 5.80 13.7
    2.5 49/0.25 2.00 6.60 8.21
    4.0 56/0.30 2.00 6.60 5.09
    6.0 84/0.30 2.00 7.60 3.39
    15 0.2 7/0.20 1.70 4.20 95
    0.35 19/0.16 1.70 4.40 53.1
    0.5 16/0.20 1.70 4.40 40.1
    0.75 24/0.20 2.00 5.20 26.7
    1.0 32/0.20 2.00 5.30 20
    1.5 30/0.25 2.00 5.30 13.7
    2.5 49/0.25 2.20 6.60 8.21
    4.0 56/0.30 2.40 7.60 5.09
    6.0 84/0.30 2.40 8.40 3.39
    20 0.2 7/0.20 1.80 4.40 95
    0.35 19/0.16 1.80 4.60 53.1
    0.5 16/0.20 1.80 4.60 40.1
    0.75 24/0.20 2.20 5.60 26.7
    1.0 32/0.20 2.20 5.80 20
    1.5 30/0.25 2.40 6.40 13.7
    2.5 49/0.25 2.40 7.00 8.21
    4.0 56/0.30 2.60 8.00 5.09
    6.0 84/0.30 2.60 8.80 3.39

    Voltage class
    (KV)
    Nominal cross section
    (mm²)
    Conductor structure
    Number/size(mm)
    Insulation
    thickness
    (mm)
    Average
    O.D
    (mm)
    At 20℃, the maximum direct current
    resistance of the conductor (Ω/km)
    25 0.2 7/0.20 2.50 5.80 95
    0.35 19/0.16 2.50 6.00 53.1
    0.5 16/0.20 2.50 6.00 40.1
    0.75 24/0.20 2.70 6.80 26.7
    1.0 32/0.20 2.70 7.00 20
    1.5 30/0.25 2.90 7.50 13.7
    2.5 49/0.25 2.90 8.00 8.21
    4.0 56/0.30 3.10 9.00 5.09
    6.0 84/0.30 3.10 9.40 3.39
    30 0.2 7/0.20 3.00 6.60 95
    0.35 19/0.16 3.00 6.80 53.1
    0.5 16/0.20 3.00 7.00 40.1
    0.75 24/0.20 3.20 7.80 26.7
    1.0 32/0.20 3.40 8.20 20
    1.5 30/0.25 3.60 9.00 13.7
    2.5 49/0.25 3.60 9.40 8.21
    4.0 56/0.30 3.80 10.30 5.09
    6.0 84/0.30 3.80 10.50 3.39
    50 0.2 7/0.20 7.00 14.60 95
    0.35 19/0.16 7.00 14.80 53.1
    0.5 16/0.20 7.00 15.00 40.1
    0.75 24/0.20 7.20 15.80 26.7
    1.0 32/0.20 7.20 16.00 20
    1.5 30/0.25 7.50 16.60 13.7
    2.5 49/0.25 7.50 17.20 8.21
    4.0 56/0.30 8.00 19.00 5.09
    6.0 84/0.30 8.00 20.00 3.39
    100 1.0 32/0.20 12.00 25.00 20
    1.5 30/0.25 13.00 27.80 13.7
    2.5 49/0.25 13.00 28.50 8.21

    Note: According to the technical agreement between the two parties, products of other specifications can also be produced.