Chemical Resistance
Radiation Resistance
Long Service Life

Single-Core Sheathed Cable (3.6/6kV) Rail Transit Low-Smoke Zero-Halogen

This single-core sheathed 3.6/6kV rail transit low-smoke zero-halogen cable is engineered for EMU and railway vehicle power and control circuits. It complies with TJ/CL 313-2014, BS 6853 and DIN 5510-2 standards. With halogen-free insulation and sheath, it features outstanding flame retardancy, low smoke density and zero toxic hydrogen chloride release when burning. It works reliably from -40°C to 90°C, offers good resistance to oil, solvent, acid and alkali, and keeps high light transmittance in fire scenarios to support safe evacuation. It is an ideal safety cable for railway rolling stock.

30 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Standards

    • Complies with TJ/CL 313-2014 Technical Requirements for EMU Wires and Cables.
    • Passes fire, smoke, and toxicity tests per BS 6853:1999 and DIN 5510-2:2009.
    • Meets BS 6853:1999 Category a, 1b, Class II requirements for internal/external vehicle cables.
    • Satisfies DIN 5510-2:2009 flammability classes S1–S5.

    Scope of Application

    • Applies to power/control cables and related circuits that reduce hazards to personnel during fires and enhance transportation safety.
    • Halogen-free insulation and sheath (with/without outer sheath).
    • Limits flame propagation, reduces toxic gas/smoke emission, maintains visibility, and facilitates rapid evacuation during fires.

    Performance Characteristics

    1. Rated Voltage (AC): 0.6/1kV, 1.8/3kV, 3.6/6kV
    2. Temperature Range: Operating: -40°C to 90°C (max. continuous temp: 90°C), Short-circuit: 200°C (5 sec), Excellent flame retardancy, low smoke & toxicity during fires.
    3. Safety: Zero chlorine content; no HCl emission during overheating/combustion.
    4. Bending Radius: Fixed installation: ≥ 5× cable OD, Non-fixed installation: ≥ 6× cable OD.
    5. LSZH Performance: Halogen gas: <5 mg/g, pH ≥ 4.3, Conductivity ≤ 10 μS/mm, Light transmittance ≥ 70%.
    6. Toxicity Index: ≤ 3 (equivalent to European standards), ≤ 5 (equivalent to railway standards).
    7. Resistant to mineral/fuel oil contamination.
    8. Passes single-core vertical flame test.
    9. Resistant to solvents, acids, and alkalis.
    10. Custom colors available.

    Product Codes & Designation

    Cable Type Designation
    Standard wall thickness, unsheathed EN 50264-2-1 0.6/1kV (1.8/3kV) M
    Standard wall thickness, sheathed EN 50264-2-1 1.8/3kV (3.6/6kV) MM

    Technical Parameters:

    Nominal cross section (mm²) Conductor diameter (mm) Insulation Average thickness (mm) Sheath average thickness (mm) Outer diameter (mm) Resistance of the conductor at 20°C Resistance of the insulation at 90°C
    min min min min max max (Ω.km) min (MΩ.km) min (MΩ.km)
    2.5 1.95 3.00 1.40 10.50 12.30 8.21 1300 13.0
    4 2.50 3.00 1.40 11.00 12.90 5.09 1150 11.5
    6 3.00 3.00 1.40 11.50 13.40 3.39 1050 10.5
    10 3.90 3.00 1.40 12.30 14.40 1.95 850 8.5
    16 5.00 3.00 1.40 13.30 15.60 1.24 710 7.1
    25 6.40 3.00 1.40 14.70 17.20 0.795 630 6.3
    35 7.70 3.00 1.40 15.90 18.60 0.565 550 5.5
    50 9.20 3.00 1.50 17.50 20.50 0.393 500 5.0
    70 11.00 3.00 1.50 19.20 22.40 0.277 430 4.3
    95 12.50 3.00 1.60 20.80 24.30 0.21 400 4.0
    120 14.20 3.10 1.70 22.70 26.60 0.164 360 3.6
    150 15.80 3.10 1.70 24.20 28.40 0.132 340 3.4
    185 17.50 3.20 1.80 26.20 30.70 0.108 330 3.3
    240 20.10 3.40 1.90 29.20 34.20 0.0817 300 3.0