Chemical Resistance
Radiation Resistance
Long Service Life

Sheathed Single-Core Cable (1.8/3kV) Rail Transit Low-Smoke Zero-Halogen

This 1.8/3kV sheathed single-core rail transit LSZH cable is designed for EMU power and control circuits. It complies with TJ/CL 313-2014, BS 6853 and DIN 5510-2 railway safety standards. Built with halogen-free insulation and sheath material, it delivers superior flame retardant performance, low smoke output and zero hydrogen chloride release when burning. It operates steadily from -40°C up to 90°C, and features reliable resistance to oil, solvents, acids and alkalis. High light transmittance during fire helps evacuation, making it a trusted safety cable for rolling stock.

27 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Standards

    • Complies with TJ/CL 313-2014 Technical Requirements for EMU Wires and Cables.
    • Passes fire, smoke, and toxicity tests per BS 6853:1999 and DIN 5510-2:2009.
    • Meets BS 6853:1999 Category a, 1b, Class II requirements for internal/external vehicle cables.
    • Satisfies DIN 5510-2:2009 flammability classes S1–S5.

    Scope of Application

    • Applies to power/control cables and related circuits that reduce hazards to personnel during fires and enhance transportation safety.
    • Halogen-free insulation and sheath (with/without outer sheath).
    • Limits flame propagation, reduces toxic gas/smoke emission, maintains visibility, and facilitates rapid evacuation during fires.

    Performance Characteristics

    1. Rated Voltage (AC): 0.6/1kV, 1.8/3kV, 3.6/6kV
    2. Temperature Range: Operating: -40°C to 90°C (max. continuous temp: 90°C), Short-circuit: 200°C (5 sec), Excellent flame retardancy, low smoke & toxicity during fires.
    3. Safety: Zero chlorine content; no HCl emission during overheating/combustion.
    4. Bending Radius: Fixed installation: ≥ 5× cable OD, Non-fixed installation: ≥ 6× cable OD.
    5. LSZH Performance: Halogen gas: <5 mg/g, pH ≥ 4.3, Conductivity ≤ 10 μS/mm, Light transmittance ≥ 70%.
    6. Toxicity Index: ≤ 3 (equivalent to European standards), ≤ 5 (equivalent to railway standards).
    7. Resistant to mineral/fuel oil contamination.
    8. Passes single-core vertical flame test.
    9. Resistant to solvents, acids, and alkalis.
    10. Custom colors available.

    Technical Parameters:

    Nominal cross section (mm²) Conductor
    diameter
    (mm)
    Insulation Average
    thickness (mm)
    Sheath average
    thickness (mm)
    Outer
    diameter (mm)
    Resistance of the conductor at 20°C Resistance of the insulation at 90°C
    min min min min max max (Ω.km) min (MΩ.km) min (MΩ.km)
    1.5 1.50 1.30 1.40 6.70 7.80 13.7 960 9.6
    2.5 1.95 1.30 1.40 7.10 8.30 8.21 850 8.5
    4 2.50 1.30 1.40 7.60 8.90 5.09 750 7.5
    6 3.00 1.30 1.40 8.10 9.50 3.39 670 6.7
    10 3.90 2.20 1.40 10.60 12.40 1.95 550 5.5
    16 5.00 2.20 1.40 11.70 13.60 1.24 450 4.5
    25 6.40 2.20 1.40 13.00 15.20 0.795 390 3.9
    35 7.70 2.20 1.40 14.20 16.60 0.565 350 3.5
    50 9.20 2.20 1.40 15.60 18.30 0.393 300 3
    70 11.00 2.20 1.50 17.50 20.50 0.277 260 2.6
    95 12.50 2.40 1.60 19.60 22.30 0.21 250 2.5
    120 14.20 2.40 1.60 21.10 24.60 0.164 220 2.2
    150 15.80 2.40 1.70 22.70 26.60 0.132 210 2.1
    185 17.50 2.40 1.70 24.00 28.10 0.108 200 2
    240 20.10 2.40 1.80 27.00 31.60 0.0817 180 1.8