Chemical Resistance
Radiation Resistance
Long Service Life

150℃ XLPE Unshielded Cable EV

This 150℃ XLPE unshielded EV cable adopts finely stranded Class 5/6 bare copper conductor and halogen-free irradiation cross-linked XLPE insulation. It supports 1500V rated voltage and works reliably within -40°C ~ +150°C. The cable features superior flexibility, heat aging resistance, oil resistance, damp heat and ozone resistance, and passes IEC/EN 60332-1-2 flame retardant test. It is widely applied for power battery wiring of electric vehicles, fuel cell vehicles, hybrid vehicles, commercial coaches and energy storage equipment.

24 people are viewing this right now
  • Check Mark Extreme Performance : Built for demanding environments.
  • Check Mark Certified Quality : Built to meet industry standards.
  • Check Mark Custom Cable Solutions : Tailored to your requirements.
  • Check Mark Technical Support : info@voltaracable.com
    Need a Custom Solution? Call us : (+01) 987-654-3210

    Product Applications

    The EV unshielded cable set is used in the power battery systems of electric vehicles, fuel cell vehicles, and hybrid electric vehicles. The product is flexible and easy to bend, with properties such as heat aging resistance, low-temperature resistance, fluid resistance, oil resistance, damp heat resistance, and ozone resistance. With a rated voltage of up to 1500V, it not only meets the requirements of general passenger vehicles but also satisfies the needs of high-power vehicles such as commercial vehicles, coaches, and buses. This product can also be used in energy storage systems.

    Product Structures

    • Conductor: Finely stranded bare copper wire, compliant with IEC 60228 / VDE 0295, Class 5/6 conductor
    • Insulation: Special halogen-free environmentally friendly irradiation cross-linked material
    • Insulation Color: Orange

    Product Features

    • Working Voltage: 1500V
    • Test Voltage: 5000V
    • Insulation Volume Resistivity: ≥ 10¹² Ω·m
    • Minimum Bending Radius: Approx. 5 × D (outer diameter of cable)
    • Operating Ambient Temperature: -40°C to +150°C
    • Flame Retardant: IEC/EN 60332-1-2
    • Reference Standards: GB/T25085, ISO19642, QC/T1037

    Technical Parameters:

    Rated Voltage Conductor cross
    section (mm²)
    Conductor construction:
    Number/size
    (mm)
    Conductor OD
    (mm)
    Insulation thickness
    (mm)
    At 20℃, the maximum direct current
    resistance of the conductor (Ω/km)
    600VAC/900VDC 1.5 48/0.20 1.8 2.3 12.7
    600VAC/900VDC 2.5 80/0.20 2.2 2.9 7.6
    600VAC/900VDC 4 56/0.20 2.8 3.5 4.71
    600VAC/900VDC 6 84/0.20 3.4 4.1 3.14
    600VAC/900VDC 10 320/0.20 4.5 5.7 1.82
    600VAC/900VDC 16 512/0.20 5.8 7.0 1.16
    600VAC/900VDC 25 798/0.20 7.2 8.4 0.743
    600VAC/900VDC 35 1120/0.20 8.5 10.0 0.527
    600VAC/900VDC 50 1591/0.20 10.5 11.8 0.368
    600VAC/900VDC 70 2229/0.20 12.5 13.9 0.259
    1000VAC/1500VDC 10 323/0.20 4.5 6.5 1.82
    1000VAC/1500VDC 16 513/0.20 5.8 7.9 1.16
    1000VAC/1500VDC 25 798/0.20 7.2 9.7 0.743
    1000VAC/1500VDC 35 1121/0.20 8.5 11.0 0.527
    1000VAC/1500VDC 50 1591/0.20 10.5 13.0 0.368
    1000VAC/1500VDC 70 2229/0.20 12.5 14.9 0.259
    1000VAC/1500VDC 95 3034/0.20 14.8 16.9 0.196
    1000VAC/1500VDC 120 3826/0.20 16.5 18.6 0.153